Strider essential series, St60f-esg, St50f-esg – SilverStone ST50F-ESG User Manual
Page 11

STRIDER ESSENTIAL SERIES
10
ST60F-ESG
:
Output
Max. step size
(% of rated output amps per Sec 3.1)
+12V
+5V
+3.3V
+5Vsb
-12V
9A (10000uF)
8A (6000uF)
8A (6000uF)
0.1A (350uF)
0.3A (6000uF)
(Adding external capactor)
ST50F-ESG
:
Output
Max. step size
(% of rated output amps per Sec 3.1)
+12V
+5V
+3.3V
+5Vsb
-12V
8A (10000uF)
8A (6000uF)
8A (6000uF)
0.1A (350uF)
0.3A (6000uF)
(Adding external capactor)
Output voltages should remain within the regulation limits of Section 3.1, and
the power supply should be stable when subjected to load transients per above
table from any steady state load, including any or all of the following conditions:
• Load-changing repetition rate of 50 Hz to 10 kHz
•AC input range per Section 2.0