3.12 CAPACITIVE LOAD
The power supply should be able to power up and operate normally with the following
capacitances simultaneously present on the DC outputs. This capacitive loading
should be used to check all of function test, but without hold-up time.
Output
ATX12V
Capacitive load (uF)
+12V
+5V
+3.3V
+5Vsb
-12V
10000
6000
6000
350
6000
3.13 CLOSED-LOOP STABILITY
The power supply shall be unconditionally stable under all line/load/transient load
conditions including capacitive loads specified in Section 3.13. A minimum of
45 degrees phase margin and 10 dB gain margin is recommended at both the
maximum and minimum loads.
4.0 PHYSICAL ENVIRONMENT
4.1 TEMPERATURE
4.1.1 Operating Ambient: +0 to 40℃
4.1.2 Non-Operating Ambient(Storage): -40℃ to +70℃
4.2 HUMIDITY
4.2.1 Operating: To 85% relative humidity (non-condensing)
4.2.2 Non-Operating: To 95% relative humidity (non-condensing)
Note: 95%RH is achieved with a dry bulb temperature of 55℃ and
a wet bulb temperature of 54℃.
4.3 ALTITUDE
4.3.1 Operating: To 10,000ft
4.3.2 Non-Operating: To 50,000ft