07
DC output
+12V1~+12V6
15.5
6.5
Max
Units
V
+5V
V
4.6
+3.3V
V
3-2. Short Circuit Protection
A short circuit placed to ground shall cause no damage or power supply
shall be shutdown.
(The contact resistance is 0.05 ohm when the outputs short circuit.)
3-3. Protection Reset
When the power supply latches into shutdown condition due to a fault
on an+5V,+3.3V,+12V1~+12V6 output( OVP, UVP), the protection
shall reset after the fault has been removed, use remote on/off control
or recycle the AC power again for a typical of 5 seconds.
3-4. Over Shoot
Any output overshoot at turn on shall be less than 15% of the nominal
output value (with resistive load) as described in sec. 2.1.
3-5. Over Power Protection
At 115/230Vac input the power supply will shut down all DC output
within 110% to 150% of full load.
4-1. Operation/Storage Temperature Range
Operation : 5℃ to 50℃
(nominal input)
Storage : -40℃ to 70℃
4. Environment
LOAD
100%
80%
60℃
50℃
08
4-2. Humidity (none condensing)
TOperation: 20% to 85% RH
(nominal input)
Storage : 10% to 95% RH
5-1. UL60950-1,
5-2. TUV EN 60950-1
5. Safety
6-1.CE
6-2.BSMI
6-3.FCC part 15 sub part J class B at system load
6-4.CISPR 22 CLASS B
6. EMI Requirements
7. Dielectric Voltage Withstand (HI-POT)
The power supply shall withstand for 3 seconds without breakdown the application
of an 1800Vac-supply voltage applied between both input line and chassis
(15mA AC Cutoff current).
Isolating transformers shall similarly withstand 4242Vdc applied between both primary
and secondary windings for a minimum of one minute.
8. PFC
Active Power Factor Correction, complies with
EN 61000-3-2: 1995+A1+A2:1998, Class D.
9. Electrostatic Discharge (ESD)
Comply with IEC 61000-4-2.
10. EFT/ Burst
Comply with IEC 61000-4-4.