2-7. Remote ON/OFF Control

The power supply outputs shall be enabled with an active-low TTL signal.
When TTL signal is low, the DC outputs are to be enabled.
When TTL signal is high or open circuited, the DC outputs are to be disabled.
Electronic means or a mechanical switch may activate the TTL signal.
After the TTL signal is active high, must wait for 3 seconds before active low again.

2-9. Power On Time (T1)

MAX

1000

Units

ms

2-10. Rise Time (T2)

MIN

1.0

MAX

50

Units

ms

2-8. Power Sequence

06

The test environment is 25℃ condition @ nominal input.

The test environment is 25℃ & full load condition @ nominal input.

2-11. Power Good Delay Time (T3)

MIN

100

MAX

500

Units

ms

2-12. Power Good Rise Time (T4)

MAX

10

Units

ms

2-13. Hold Up Time (T5)

MIN

16

Units

ms

2-14. Power Fail Signal (T6)

MIN

1.0

Units

ms

Power good signal shall go to a down level 1ms before +5V output voltage falls
below the regulation limits during PS-ON signal pull high.

3-1. Over Voltage Protection

When the DC outputs (+5V, +12V1~+12V6, +3.3V) have over voltage condition,
the power supply shall provide latch mode over voltage protection.

3. Protections