beautypg.com

Manual-sst-zm1350-v1-p3-p4, Zeus series – SilverStone ZM1350 User Manual

Page 3

background image

ZEUS SERIES

03

2-3. Cross Regulation

The DC loads shall remain within the ranges specified in 2-2 DC Load Requirements
and the DC output voltages also shall remain within the regulation ranges specified
in 2-1 Output Regulation when measured at the load end of the output connectors.

Note: 1). The above voltage range should also include ripple and noise.
2). The output voltage should be measured at the terminals of output connector.

Note : 1). The maximum continuous total DC output power shall not exceed1350 Watts.

2-1. Output Regulations

The power supply shall be operated at universal input voltage defined in the following
table.

2. Output Requirements

Output Voltage

Range

+5V

1%

1%

MIN

Nominal

MAX

Units

-

+

+4.95

+5.00

+5.05

Volts

+12V1~V6

-

+

+11.88

+12.00

+12.12

Volts

10%

-12V

-

+

-10.80

-12.00

-13.20

Volts

1%

+3.3V

-

+

+3.26

+3.30

+3.33

Volts

5%

+5Vsb

-

+

+4.75

+5.00

+5.25

Volts

2-2. DC Load Requirements

Output Voltage

+5V

1.0

1.0

MIN

NOM

MAX

Units

12.5

25

AMPS

+12V1~V6

15

30

AMPS

0.0

-12V

0.25

0.5

AMPS

1.0

+3.3V

12.5

25

AMPS

0.1

+5Vsb

2

4

AMPS

3). The maximum continuous combined load on +12V1outputs shall not exceed 1260 Watts.

2). The maximum continuous combined load on +5V and +3.3V outputs shall not exceed 170 Watts.

4). The maximum continuous combined load on +5V, +3.3V and +12V1~+12V6 outputs shall
not exceed 1324Watts.

04

2-4. +5V standby voltage

The +5Vsb is on whenever the AC power is present.

2-5. DC Output Voltage Ripple and Noise

1350W C ross R egulation

(5V rail +3.3V vs. 12V )

0

50

100

150

200

150

300

450

600

750

900

1050

1200

12V pow er (w atts)

5V

+3

.3V

po

we

r

(wa

t

ts

)

3.3V&+5V power (watts)

Output Voltage

+5V

20

25

Ripple & Noise Max

U

Operation : nits

mV

+12V1~V6

mV

120

-12V

mV

20

+3.3V

mV

50

+5Vsb

mV

2-5. DC Output Voltage Ripple and Noise

MAX

1350

Units

Watts

Note : 1)The measurements should be made by crossing a 10uF/ electrolytic and a 0.1uF ceramic disk
capacitors at each output with measuring bandwidth from DC to 20 MHz. If ambient temperature
is under 20℃ or over 30℃, the AC input should be nominal input.