Manual-sst-zm1350-v1-p3-p4, Zeus series – SilverStone ZM1350 User Manual
Page 3

ZEUS SERIES
03
2-3. Cross Regulation
The DC loads shall remain within the ranges specified in 2-2 DC Load Requirements
and the DC output voltages also shall remain within the regulation ranges specified
in 2-1 Output Regulation when measured at the load end of the output connectors.
Note: 1). The above voltage range should also include ripple and noise.
2). The output voltage should be measured at the terminals of output connector.
Note : 1). The maximum continuous total DC output power shall not exceed1350 Watts.
2-1. Output Regulations
The power supply shall be operated at universal input voltage defined in the following
table.
2. Output Requirements
Output Voltage
Range
+5V
1%
1%
MIN
Nominal
MAX
Units
-
+
+4.95
+5.00
+5.05
Volts
+12V1~V6
-
+
+11.88
+12.00
+12.12
Volts
10%
-12V
-
+
-10.80
-12.00
-13.20
Volts
1%
+3.3V
-
+
+3.26
+3.30
+3.33
Volts
5%
+5Vsb
-
+
+4.75
+5.00
+5.25
Volts
2-2. DC Load Requirements
Output Voltage
+5V
1.0
1.0
MIN
NOM
MAX
Units
12.5
25
AMPS
+12V1~V6
15
30
AMPS
0.0
-12V
0.25
0.5
AMPS
1.0
+3.3V
12.5
25
AMPS
0.1
+5Vsb
2
4
AMPS
3). The maximum continuous combined load on +12V1outputs shall not exceed 1260 Watts.
2). The maximum continuous combined load on +5V and +3.3V outputs shall not exceed 170 Watts.
4). The maximum continuous combined load on +5V, +3.3V and +12V1~+12V6 outputs shall
not exceed 1324Watts.
04
2-4. +5V standby voltage
The +5Vsb is on whenever the AC power is present.
2-5. DC Output Voltage Ripple and Noise
1350W C ross R egulation
(5V rail +3.3V vs. 12V )
0
50
100
150
200
150
300
450
600
750
900
1050
1200
12V pow er (w atts)
5V
+3
.3V
po
we
r
(wa
t
ts
)
3.3V&+5V power (watts)
Output Voltage
+5V
20
25
Ripple & Noise Max
U
Operation : nits
mV
+12V1~V6
mV
120
-12V
mV
20
+3.3V
mV
50
+5Vsb
mV
2-5. DC Output Voltage Ripple and Noise
MAX
1350
Units
Watts
Note : 1)The measurements should be made by crossing a 10uF/ electrolytic and a 0.1uF ceramic disk
capacitors at each output with measuring bandwidth from DC to 20 MHz. If ambient temperature
is under 20℃ or over 30℃, the AC input should be nominal input.