6
Label 14
Label 15
Label 16
45
Internal connections of the electrical heating
3 AC
1 AC
Technical remarks
Heating
3x230V
R5
3x400V
R5
12kw
3x2kw
3x2kw
See label 14
See label 14
LC1D1810
LC1D1810
See label 15 LC1D0901
15kw
3x2kw
3x3kw
See label 14
See label 14
LC1D1810
LC1D1810
See label 15 LC1D1810
18kw
3x3kw
3x3kw
See label 14
See label 14
LC1D1810
LC1D1810
See label 15 LC1D1810
21kw
3x3kw
3x4kw
--------
--------
See label 16
See label 16
LC1D1810
LC1D1810
24kw
3x4kw
3x4kw
--------
--------
See label 16
See label 16
LC1D1810
LC1D1810
Heating
R5
3kw
LC1D0901
NOTE:
Other executions are available as options.
B = Black
Br = Brown
Gy = Grey
Or = Orange
R = Red
W = White
Table 9
Table 10