6

Label 14

Label 15

Label 16

45

Internal connections of the electrical heating

3 AC

1 AC

Technical remarks

Heating

3x230V

R5

3x400V

R5

12kw

3x2kw

3x2kw

See label 14

See label 14

LC1D1810

LC1D1810

See label 15 LC1D0901

15kw

3x2kw

3x3kw

See label 14

See label 14

LC1D1810

LC1D1810

See label 15 LC1D1810

18kw

3x3kw

3x3kw

See label 14

See label 14

LC1D1810

LC1D1810

See label 15 LC1D1810

21kw

3x3kw

3x4kw

--------

--------

See label 16

See label 16

LC1D1810

LC1D1810

24kw

3x4kw

3x4kw

--------

--------

See label 16

See label 16

LC1D1810

LC1D1810

Heating

R5

3kw

LC1D0901

NOTE:

Other executions are available as options.

B = Black

Br = Brown

Gy = Grey

Or = Orange

R = Red

W = White