The connection should be shielded in a liquid tight or approved flexible conduit with proper

conductors of correct size installed in accordance with the National Electric Code or other

applicable codes. The connection must be made by a qualified electrician using the wiring diagram

provided with the washer-extractor, or according to accepted European standards for CE-approved

equipment.

Use wire sizes indicated in Table 3 through 7 for runs up to 50 feet.

Use next larger size for runs of 50 to 100 feet. Use two sizes larger for runs greater than 100 feet.

For personal safety and proper operation, the washer-extractor must be grounded in accordance

with state and local standards. If such standards are not available, grounding must conform to the

National Electric Code, article 250-95. The ground connection must be made to a proven earth

ground, not to a water pipe, gas pipe, or another metal pipe. Provide the necessary equipotential

connections according to the local electrical prescriptions.

GROUNDING INSTRUCTIONS
This appliance must be connected to a grounded metal, permanent wiring system; or an equipment-

grounding conductor must be run with the circuit conductors and connected to the equipment-

grounding terminal or lead on the appliance.

IMPORTANT: Alliance Laundry Systems Warranty does not cover components that fail as a

result of improper input voltage.