Operation, Air compressor controls (24 thru 27), Battery jump start terminal (28-31) – Lincoln Electric AIR VANTAGE IM10065 User Manual
Page 24
b-5
OPERATION
b-5
20. CIRCUIT bREAKERS
These circuit breakers provide separate overload
current protection for each 120V circuit at the
240V single phase receptacle, each 120V single
phase receptacle, the 240V three phase recepta-
cle, the 120VAC in the 14-Pin connector, the
42VAC in the 14-Pin connector and battery circuit
overload protection.
21. 120VAC SINGLE PHASE RECEPTACLES
These two 120VAC (5-20R) receptacles with
ground fault circuit interruption protection provide
120VAC single phase for auxiliary power. Each
receptacle has a 20 amp total rating. They are
designed to protect the user from the hazards of
ground faults. When the GFCI has tripped there
will be no voltage available from the receptacle.
Refer to the AUXILIARY POWER RECEPTA-
CLES section in the installation chapter for further
information about these receptacles. Also refer to
the AUXILIARY POWER OPERATION section
later in this chapter.
22. GROUND STUD
Provides a connection point for connecting the
machine case to earth ground. Refer to
“MACHINE GROUNDING” in the Installation chap-
ter for proper machine grounding information.
23. 240VAC THREE PHASE RECEPTACLE
This is a 240VAC (15-50R) receptacle that pro-
vides 240VAC three phase auxiliary power. This
receptacle has a 50 amp rating.
AIR COMPRESSOR CONTROLS (24
THRU 27)
24. COMPRESSOR ON/OFF SWITCH
Turns compressor on and off activating or deacti-
vating the electromagnetic compressor clutch.
25. COMPRESSOR PROTECTION LIGHT
The yellow compressor protection light remains
off with proper compressor oil temperatures. If the
lights turn on, the compressor protection system
will deactivate the compressor clutch and put the
system in standby mode until the temperature
reaches allowable limits. Check for proper com-
pressor oil level.
26. COMPRESSOR HOUR METER
The compressor hour meter displays the total
time that the compressor has been running (com-
pressor switch must be on).
27. AIR DISCHARGE VALVE
Controls flow of compressed air. A 3/4” NPT
(National Pipe Thread) fitting is provided.
bATTERY JUMP START TERMINAL
(28-31)
28. POSITIVE bATTERY JUMP START
TERMINAL.
29. NEGATIVE bATTERY JUMP START
TERMINAL.
12V battery jump start feature is standard.
Covered output studs for convenient access, and
protection against accidental impact. can be used
to jump-start a utility truck with up to 800 cold
cranking amps. Can also be used to jump-start the
AIR VANTAGE® 500 CUMMINS.
30. bATTERY DISCONNECT SWITCH
Battery disconnect switch provides lockout/tagout
capability. Switch is conveniently located on the
front bottom of the machine.
31. AIR CLEANER AND SERVICE INDICATOR
Air cleaner service indicator provides a Go/No-Go
visual indication of useful filter service life. Also
located inside the engine compartment. (SEE FIG-
URE B.2)
FIGURE b.2
AIR VANTAGE® 500 CUMMINS
31