Setup – Robinair 34988 Recovery, Recycling, Recharging Unit User Manual
Page 8
6
Power Up the Unit
1. Unwind the power cord from the handle, and
plug it into a correct voltage outlet.
2. Turn on the main power switch. The first time
the unit is powered up, it displays the initial
setup mode.
Select Language
The operator may choose to have prompts
displayed in one of three languages: English,
French, or Spanish.
1. Use the UP or DOWN arrow key to toggle through
the choices. Refer to Figure 3.
2. Select SAVE to choose the displayed language.
UV Dye Inject Bottle
1. Unscrew the lid from the UV dye
reservoir and remove the piston.
2. Fill the reservoir with UV dye only to the
MAX FILL line. Overfilling the reservoir
will compromise the o-ring seal and may
cause air to be injected into the vehicle
system.
3. Spread a thin film of oil or dye on the piston
o-ring (to reduce seal drag), and thread the lid
onto the reservoir.
4. Slowly push the piston into the reservoir unil you
see dye at the connector.
5. Inspect the dye reservoir bottle to ensure there
are no air bubbles between the piston and the
UV dye—the piston should be in direct contact
with the dye.
6. Refer to Figure 2. Hold the assembly by the
connector while supporting the bottom of the
plastic bottle to keep the piston in contact with
the UV dye. Snap the connector into the coupler
on the unit.
7. Inspect the bottle again to ensure there are no air
bubbles between the piston and the UV dye—the
piston should be in direct contact with the dye.
Note: To remove the UV dye bottle from the coupler,
press the release button on the coupler and pull the
bottle straight down.
Setup
Figure 2
UV Dye
Bottle
Release Button
Keypad
Arrow
Keys
Figure 3