Operating instructions – Robinair ACR2005 Air Conditioning and Refrigerant Service Solution User Manual
Page 25

23
ACR2005 Refrigerant Service Solution
RECOVER
• Verify the service hoses are connected and the coupler valves are open.
• The system must have at least 25 psi of pressure for correct operation of
the refrigerant ID.
SETUP MENU
(Use the
UP/DOWN
arrows to highlight selections.)
• Language
- Press TOGGLE SELECTION to select English, Spanish, or French.
- Press the
MAIN
key to exit.
• Select Units (Selects the units of measure in English or Metric.)
- Press TOGGLE SELECTION.
- Press the
MAIN
key to exit.
• Clock Adjust (Adjusts the date and time.)
- Press the
ENTER
key.
- Use the
UP/DOWN
arrows to change the date and time.
• Change Elevation (Sets the altitude above sea level for your location.)
- Enter the numeric value.
• Calibrate Pressure (Calibrates high- and low-side pressure transducers.)
- Disconnect service hoses, and press the
ENTER
key.
• Anemometer (Enables and calibrates optional anemometer.)
- Instruction detail included with the anemometer.
• Manual Oil Drain (Allows user to manually drain any oil from the
ACR2005.)
- Press the
ENTER
key.
- Press the
EXIT
key.
• Hose Length
- Allows accurate charging with varying lengths of hose.
• Refrigerant Management
- Displays details on refrigerant usage.
Operating Instructions