Setup – Robinair 34788-I Recovery, Recycling, Recharging Unit User Manual
Page 7
5
539602 Rev. H June 11, 2013
Setup
Unpack the Accessory Kit
Unpack the accessory kit from the bag, and remove the
plastic packaging. The kit consists of
• A calibration weight.
• Vacuum pump oil, oil filler cap, and tube.
• Plastic pouch containing a warranty card (to be
completed and mailed), applicable MSDS sheets, a
service center listing, and an envelope of Mobile Air
Conditioning Society (MACS) information.
Important: You must complete and mail the MVAC
Certification Form and your technicians must be
certified with the Environmental Protection Agency
(EPA) to operate this equipment.
Power Up the Unit
1. Unwind the power cord from the handle, and plug it
into a correct voltage outlet. See Figure 1.
2. Turn on the main power switch. The first time the unit
is powered up, it displays the initial setup mode.
Select a Language – English
Seleccionar Idioma – Espanol
Selection Langue – Francais
The operator may choose to have prompts displayed in
one of three languages: English, Spanish, or French.
1. Use the UP or DOWN arrow key to toggle through
the choices for English, Spanish, or French. Refer to
Figure 2.
2. Press START / YES to select the displayed language.
Select Operating Units
The operator may choose to have test results displayed
in Imperial (lb., or lb. and oz.) or Metric (kg) units.
1. Use the UP or DOWN arrow key to toggle through
choices for IMPERIAL UNITS or METRIC UNITS.
2. Press START / YES to select the displayed operating
unit choice.
CAUTION: R-134a systems have special
fittings (per SAE specifications) to avoid
cross-contamination with R-12 systems.
DO NOT adapt your unit for a different
refrigerant — system failure will result.
Arrow
Keys
Start / Yes
Button
Figure 2
Stop / No
Button
Power
Cord
Main
Power Switch
Figure 1