Circuit
Breaker
Figure 10
Back View
Maintenance
General Maintenance
1. On a regular basis, wipe off the unit using a clean
cloth to remove grease and dirt.
2. Periodically check internal components for leaks; over
time, fittings can loosen as the unit is moved. Open
the door panel, and trace lines using a leak detector.
Check connections on the back of the unit. Tighten
any loose fittings or connections you may find.
Electrical Protection
The unit is equipped with a 15 amp circuit breaker on
the back panel. See Figure 10. If the breaker trips, its
button will pop out. A tripped circuit breaker will cause
the unit to lose all power.
Press the circuit breaker button to reset.
Manually Fill the
Internal Storage Vessel (ISV)
This menu item is used to transfer refrigerant from a
source tank to the internal storage vessel.
Note: If a refrigerant source tank remains connected to
the unit during normal operation, the correct amount of
refrigerant will automatically be maintained in the ISV.
The ISV may be manually refilled, if necessary.
1. Press Menu, and use arrow keys to select MANUAL
REFILL. Press START / YES. The unit displays
CONNECT SOURCE TANK
START TO BEGIN
2. Connect the fill hose to a full source tank, and open
the source tank valve.
3. Install the source tank, and secure it to the unit
with the source tank strap in such a way that liquid
refrigerant is supplied to the connection.
4. Press START / YES to begin. The display shows
TANK FILL IN PROGRESS
TRANSFER XX LBS
5. The unit automatically stops when the preset tank fill
level is reached, or press STOP / NO to exit.
Figure 11
Side View
Fill Hose
Power
Cord
Source
Tank
Strap
Low- and
High-Side
Hoses