Wiring diagram (cont’d), Furnace / fan-coil / heat pump interlock, For a furnace connected to a cooling system – Reversomatic Deluxe Series User Manual

Page 5

background image

Never connect a 120 volt AC circuit to the terminals of the furnace

interlock (Standard Wiring).

Only use the low voltage class 2 circuit.

/fan-coil/heat pump

W A R N I N G

!

!

On some older thermostats, energizing the R and G terminals at the furnace has the effect of energizing Y at the
thermostat and thereby turning on the cooling system. If you identify this type of thermostat, you must use the
“Alternate Interlock Wiring”.

For a furnace connected to a cooling system:

Wiring Diagram (cont’d)

3

Furnace / Fan-Coil / Heat Pump Interlock:

Standard Interlock Wiring

INTERLOCKING

RELAY

W

R

G

Y

W

R

G

Y

C

FOUR WIRE

TWO WIRE
heating only

Cooling
System

FURNACE / FAN-COIL / HEAT PUMP
24-VOLT TERMINAL BLOCK

THERMOSTAT TERMINALS

TWO WIRE