9040 Cascade Low Voltage Control Unit - Installation
>
>>
>
> The 9040 Cascade control unit MUST
MUST
MUST
MUST
MUST be
located outside the hazardous area. (See
NFPA-33, OSHA, and ITW Ransburg
Literature “Operating Your Electrostatic
Coating System Safely”.)
>
>>
>
> The user MUST
MUST
MUST
MUST
MUST read and be familiar with
the SAFETY and SAFETY PRECAUTIONS.
>
>>
>
> This manual MUST be read and thoroughly
understood by ALL personel who operate,
clean, or maintain this equipment! Special
care should be taken to ensure that the
WARNINGS and requirements for operating
and servicing safely are followed. The user
should be aware of and adhere to ALL local
building and fire codes and ordinances as
well as NFPA-33 and OSH prior to installing,
operating, and/or servicing this equipment.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
>
As each installation is unique, this
information is intended to provide
gener-
gener-
gener-
gener-
gener-
al
al
al
al
al installation information for the 9040
Cascade control unit. Consult your au-
thorized ITW Ransburg representative
for
specific
specific
specific
specific
specific directions pertaining to the
installation of your equipment.
N O T E
N O T E
N O T E
N O T E
N O T E
LOCA
LOCA
LOCA
LOCA
LOCATION
TION
TION
TION
TION
Install the 9040 Cascade control unit in an area
outside the hazardous location, where it will be
protected from the possibility of environmental
intrusion, such as dust or moisture, and ambient
temperatures do not exceed 120
°F, but as close
to the applicator as possible to minimize the length
of low voltage cable. The control unit may be free
standing on any flat surface or rack mounted in
any 19-inch or Eurorack cabinet.
> DO NOT
DO NOT
DO NOT
DO NOT
DO NOT locate the control unit near
or adjacent to heat producing equipment
such as ovens, high wattage lamps, etc.
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
!!!!!
>
When rack mounting the 9040 Cas-
cade control unit in a 19-inch cabinet or
Eurorack, it may be necessary to remove
the rubber feet from the bottom of the
9040 enclosure.
N O T E
N O T E
N O T E
N O T E
N O T E
INPUT CONNECTIONS
INPUT CONNECTIONS
INPUT CONNECTIONS
INPUT CONNECTIONS
INPUT CONNECTIONS
For non-conduit installations, plug the detachable
AC line cord into the receptacle in the rear of the
9040 Cascade control unit. Plug the other end of
the line cord into a properly grounded 120-volt AC
outlet.
>
In general, conduit must be used for
approved AC installation; however, if na-
tional and local codes permit, the AC
power may be supplied via the factory
supplied line cord. If conduit is utilized,
the control unit AC input wiring may be
routed through an optional explosion proof
switch mounted on or near the spray
booth where it will be convenient to the
operator.