Troubleshooting guide, Dr-1 fluid regulator - maintenance – Ransburg DR-1 Fluid Regulator 74151 User Manual

Page 17

background image

DR-1 Fluid Regulator - Maintenance

14

TROUBLESHOOTING GUIDE

General Problem

Cause

Solution

No Fluid Flow

Fluid Will Not Shut Off

Paint Leakage

Air Leakage

Low Fluid Flow

1. Plugged fluid inlet

2. Item 11 (regulating needle

and seat) stuck

3. No pilot air

4. Ruptured Item 9 (upper

diaphragm)

5. Ruptured Item 14 (center

diaphragm)

1. Dirt in Item 11 (regulating

needle/seat)

2. Pilot air not shut off

3. Broken Item 12 (spring)

1. Item 4 (screws) loose

2. Ruptured Item 8 (lower

diaphragm)

3. Item 13 (retaining plug)

loose

4. Loose fluid fitting

5. Item 10 (o-ring) pinched

1. Loose air fitting

2. Item 4 (screws) loose

3. Ruptured Item 9 (upper

diaphragm)

4. Ruptured Item 14 (center

diaphragm)

1. Incorrect regulator ratio

2. Fluid supply pressure to low.

3. Air pilot to low.

1. Flush clean.

2. Remove and clean or replace.

3. Check air pilot signal.

4. Rebuild regulator.

5. Rebuild regulator.

1. Remove and clean or replace. (Must be

replaced as a set, see "Maintenance"

section.)

2. Check signal air supply.

3. Replace item 12 (spring).

1. Tighten per "Assembly Procedure" in the

"Maintenance" section.

2. Rebuild regulator.

3. Tighten, torque to 25-30 lbs

ft (see

"Maintenance" section).

4. Tighten.

5. Replace Item 10 (o-ring).

1. Tighten.

2. Tighten.

3. Rebuild regulator.

4. Rebuild regulator.

1. Refer to "Operations" section for correct

sizing information.

2. Increase fluid supply pressure. (Do not

exceed 100 psig (see "Specifications" in the

"Introduction" section).

3. Check air pilot signal.

(Continued on next page)

LN-9223-00.10