background image

>

Expect alarm light to flash when auto

tuning.

NOTE

USER Key

Press this key in monitoring mode display or setup

mode display returns you to the PV/SV display.

Pressing this key on the PV/SV display allows

you to set the function for uTey under the system

menu (5Y5 Ch 7). (The factory set function for

this key is switching between auto and manual.)

SEL Key

Switches the PV/SV display to the monitoring

mode display or setup mode display. Switches

to setup mode when parameter display and this

key functions as the select key when changing

parameters. Holding this key down in channel

display or parameter display returns you to the

PV/SV display. Pressing this key at PV/SV display

in manual mode, manual output value is shown

in the lower display.

Key

Pressing once will increase the setting value by

one. Holding down the button will continue to

increase the value. It changes SV on the PV/

SV display. It is also used to move between

items in channel screen display and parameter

screen display.

Key

Pressing once will decrease the setting value

by one. Holding down the button will continue

to decrease the value. It changes SV on the

PV/SV display. It is also used to move between

items in channel screen display and parameter

screen display.

OPERATION PARTS

Display

C1/C2 Lamp

Displays the condition of the control output. Lights

ON at 100% output and goes out at 0% output.

For values between 0% and 100%, the output is

indicated by the length of time the lamp flickers.

When acting as a valve control, the C1 lamp will

light with OPEN output, and the CS lamp will flicker

with CLOSE output.

DO1/2/3 Lamp

Lights ON when there is digital output is on state

(DO1, DO2, DO3). The lamp flickers when delay

behavior is on.

PV Display

Displays the measurement value (PV). Displays

the name of the parameter when setting parameters.

SV Display

Displays the set value (SV). Also can display the

output value during manual mode. Displays the

parameter setting value when setting parameters.

Displays (rEN) during remote SV operation and

5oF

R

and set value alternately during soft start.

SV Lamp

Lights when displaying the set value (SV). Goes

out when displaying the manual output value. The

lamp flickers while performing ramp soak or lamp

SV operations.

MAN/AT/SELF Lamp

Normally lights up during manual mode and blinks

during auto-tuning or self-tuning.

DISPLAY

Air Heater Assembly - Installation

12

LN-9245-00.8