beautypg.com

Ransburg Air Heater Assy. A11065-05 User Manual

Page 14

background image

>

Air filters must be located before the

air heater. Heated air may damage air

filters.

>

The use of an in-line lubricator before

the air heater is

NOT recommended. Oil

laden air passing across the heating ele-

ments results in burnt contaminates which

will accumulate and plug applicator ports.

This action may cause premature atom-

izer turbine failure.

>

It is the user's responsibility to

ensure clean air at all times. Failures

resulting from contaminated air will

not be covered under warranty.

C A U T I O N

!

FRONT PANEL DISPLAY AND FUNCTIONS

FUJI MICRO CONTROLLER "X", MODEL PXG4

Air Heater Assembly - Installation

11

LN-9245-00.8