Recommended air filtration for the air

heater is 50 micron and must be free of

oil. Additional filtration may be required

depending on applicator used. (Refer to

Applicator manual for required filtration.)

NOTE

>

DO NOT operate air heater without a

minimum of 1 SCFM of air flow through

the unit.

W A R N I N G

!

INSTALLATION OPTIONS

(See Figure 1)

Heater Pressure Switch Interlock Options for

Activation:

1. Pilot from one of the following items which

corresponds and signals air is flowing:

a. Volume booster - requires a minimum of 1

psig.

b. PLC pneumatic output - requires a mini-

mum

of 1 psig.

c. Air regulator - requires a minimum of 1 psig.

2. Directly from a remote electrical control (such

> Never activate heater without air flow.

C A U T I O N

!

as a turbine speed control or PLC). This contact

must correspond and signal that air is flowing

through the heater.

This electrical circuit must be connected using a

minimum 1 amp dry contact relay (such as PLC

contact). This can be completed by the following:

1. Remove the present wire from TB8-1.

2. Using a wire nut, connect the wire removed in

step 1 to a longer wire and route to one side of

the remote contact.

3. Run a wire from the other side of the remote

contact back to TB8-1.

4. Add pressure switch changes, A1.

When the remote contact is closed, the air heater

will turn on.

Air Heater Assembly - Installation

9

LN-9245-00.8