Ransburg, Specifications, Environmental/physical – Ransburg Discrete IO Module A11435 User Manual
Page 10: Electrical, Electrical (cont.), Discrete i/o module - safety

SPECIFICATIONS
Environmental/Physical
Operating Temperature:
0°C to 55°C
Storage Temperature:
-40°C to 85°C
Humidity:
0 to 95% non-
condensing
Size:
100 X 160 mm
Eurocard
Module,
1
inch
wide
Electrical
Electrical Power
Required:
24 VDC @ 0.11 A or
28 VDC @ 0.10 A
I
nput current does not include that required by
analog and digital outputs. 24 VDC and 28 VDC
must be regulated and have over-current (40%) and
over-voltage (20%) protection.
Electrical I/O:
(Connection points listed in Tables 1, 2, 3, and 4)
Analog In:
(0-10 VDC or 4-20 mA)
kV
Set
Current Set (Over-Current
Setpoint)
Atomizer
Speed
Set
Di/dt
Set
Analog Out:
(0-10 VDC or 4-20 mA)
Output
kV
Output
Current
Atomizer
Speed
Atomizer
Drive
Pressure
Electrical (Cont.)
Digital In:
(24 VDC Source or Sink)
HV
On
HV
Off
Fluid
Trigger
Air
Trigger
Di/dt
Disable
Bell
Spin
Enable
Digital Out:
(Dry Contact)
Bell
Running
HV
Ready
HV
On
Over-Current
Fault
Feedback
Fault
Analog Input In Local
Overspeed
Fault
Underspeed
Fault
Loss
of
Feedback
Invalid
Speed
Command
Low
Bearing
Air
Fault
Speed
Out
of
Tolerance
Discrete I/O Module - Safety
7
LN-9253-06.1
Ransburg