MAINTENANCE

>

Electrical shock hazard. ALWAYS

turn power to equipment OFF prior to

cleaning or servicing any part of the

system. Failure to do so could result in

serious injury or death.

>

Whenever removing high voltage

cable(s) from equipment, ground the plug

end of the cable(s) by contacting the plug

to electrical ground. Do not touch the

plug until it has been grounded. This will

eliminate the possibility of residual charge

causing electrical shock.

>

Whenever the high voltage cable is

removed from the LEPS5001 Power Sup-

ply, ALWAYS discharge any residual high

voltage charge from the power supply by

attaching an appropriate ground wire to

the grounded power supply container and

then inserting it down the free end of the

high voltage tube.

>

To assure continuous, efficient, trou-

ble-free operation of the LEPS5001 Pow-

er Supply and to extend its service life,

keep the exterior clean and dry. It is also

very important to keep the areas around

the high voltage cable connections clean,

to protect against static discharges.

W A R N I N G

!

TROUBLESHOOTING

When tracing problems, refer to the schematic

Periodically clean the unit with a clean, dry,

lint-free cloth and visually inspect for any loose

wiring connections.

Remove the high voltage cables, make sure

that they are clean and reinsert into the power

supply.

>

Apply a liberal amount of dielectric

grease (59972-00) to the high voltage ca-

ble plug before inserting back into the pow-

er supply.

>

Make sure that the high voltage cables

are fully inserted into the power supply and

that the strain relief connections are se-

cure.

NOTE

in Figure 3, illustrations in Figures 5a and 5b,

"Theory of Operation" and "Parts Identification"

sections of this manual, and the LECU5003

Control Panel service manual.

If a high voltage output problem is suspected in

the system, perform the following troubleshoot-

ing procedure:

Equipment required: Ransburg High Voltage

Test Probe and Meter (20791) AC RMS Voltme-

ter (150 volt scale or greater)

1.

With the power OFF, remove the cov-

er from the junction box that houses

>

Field repair and troubleshooting of the

LECU5003 Control Panel may require expo-

sure to potentials that can cause SERIOUS

BODILY INJURY or DEATH if proper pro-

cedures are not followed. For this reason,

troubleshooting and field repair should only

be accomplished with specific test equip-

ment by qualified electronics technicians or

authorized Ransburg representatives.

W A R N I N G

!

LEPS5001 Power Supply - Maintenance

14