beautypg.com

Ransburg – Ransburg LEPS5001 Power Supply for LECU5003 User Manual

Page 13

background image

>

Whenever removing high voltage ca-

ble(s) from equipment, ground the plug end

of the cable(s) by contacting the plug to

electrical ground. Do not touch the plug until

it has been grounded. This will eliminate the

possibility of residual charge causing electri-

cal shock.

W A R N I N G

!

>

If a high voltage junction tank or switch

tank is to be used in the system, refer to

the appropriate service manual for cable

terminations and installation requirements.

NOTE

8.

Make cable runs as short as possible by

mounting the power supply as close to

the spray device as codes and environ-

ment allow.

Cut the high voltage cable (SSW-1064) ac-

cording to the length required and screw an

EPS-4245 connector (supplied as part of the

LKIT0003 Connection Kit) onto the cable end

which will be inserted into the power supply. Be

careful to keep the screw centered in the middle

of the cable as it is installed. Thread the cable

end through the metal nut and then through

the rubber bushing (supplied as part of the

LKIT0003 Kit). Insert the cable fully into a high

voltage output of the power supply, then tighten

the nut until the cable is secure. Tighten the nut

retaining screw with very light force (see Figure

4). An LKIT0003-00 Connection Kit is required

for each high voltage cable connection to the

power supply or junction tank when using SSW-

1064 cable.

NOTES:

LEPS5001 Power Supply - Installation

10

Ransburg

CP-95-02.5