Whenever removing high voltage ca-
ble(s) from equipment, ground the plug end
of the cable(s) by contacting the plug to
electrical ground. Do not touch the plug until
it has been grounded. This will eliminate the
possibility of residual charge causing electri-
cal shock.
W A R N I N G
!
>
If a high voltage junction tank or switch
tank is to be used in the system, refer to
the appropriate service manual for cable
terminations and installation requirements.
NOTE
8.
Make cable runs as short as possible by
mounting the power supply as close to
the spray device as codes and environ-
ment allow.
Cut the high voltage cable (SSW-1064) ac-
cording to the length required and screw an
EPS-4245 connector (supplied as part of the
LKIT0003 Connection Kit) onto the cable end
which will be inserted into the power supply. Be
careful to keep the screw centered in the middle
of the cable as it is installed. Thread the cable
end through the metal nut and then through
the rubber bushing (supplied as part of the
LKIT0003 Kit). Insert the cable fully into a high
voltage output of the power supply, then tighten
the nut until the cable is secure. Tighten the nut
retaining screw with very light force (see Figure
4). An LKIT0003-00 Connection Kit is required
for each high voltage cable connection to the
power supply or junction tank when using SSW-
1064 cable.
NOTES:
LEPS5001 Power Supply - Installation
10