CONNECTIONS

TO LECU5003

CONTROL PANEL

Route the control cable from the LEPS5001

Power Supply through one of the external

wiring grommets located on the bottom of the

control panel, and connect to the control panel

terminal block as described in Figure 1. After

making the connections, tighten the external

wiring grommet around the black heat shrunk

portion of the control cable. In general, con-

duit should be used to route the control cable

(check your local codes for conduit require-

ments). Figure 3 shows a schematic of the

LEPS5001 Power Supply and its connections to

the LECU5003 Control Panel.

>

The LEPS5001 Power Supply can also

be used with older model 17264 Control

Panels. For wiring connections, refer to

Figure 2.

NOTE

HIGH VOLTAGE CABLE

-ROUTING & GENERAL GUIDELINES

SSW-1064

Unshielded High Voltage Cable

According to OSHA standard 1910.107,(h)(5),

high voltage cable “shall be properly insulated

and protected from mechanical injury or ex-

posure to destructive chemicals”. To facilitate

compliance with this code, the following recom-

mendations

must be followed:

1.

Never route cables so that they lie on

the floor or are subject to vehicular traffic.

2.

Never route cables from different power

supplies along parallel paths unless they

are separated by at least 18 inches.

3.

Always route cables along appropriate

insulators.

4.

Always properly support cables at least

12 inches from metal beams. The sup-

port should be made of material that

does not conduct electricity, such as

most plastics. Ransburg part number

45773-011 is one such support.

5.

Always route cables from overhead,

down to the applicator.

>

Sheathing is NOT a safe method of pro-

tecting a cable from wear or traffic!

W A R N I N G

!

6.

If an insulating sheathing is used around

the cable, it

MUST be of a nonabsor-

bent material, such a polyethylene, and

should be routed to prevent contact with

or entrapment of solvents or cleaning

solutions. The cable should

NOT be

sheathed from its last point of physical

support after it enters the spray area, to

the applicator! Insulating sheathing is

available from Ransburg as part number

9704-13.

7.

If a cable must be routed through a met-

al (or conductive) surface, cut an open-

ing with a minimum radius of five inches

and mount a nonconductive bulkhead

therein. Route the cable through the

center of the bulkhead and secure it with

a suitable, nonconductive strain relief.

(The opening may be any configuration

as long as there is at least five inches

from the nearest conductor.)

>

Do NOT make the approach to the ap-

plicator at or below floor level. Route high

voltage cables from overhead down to the

applicator. Routing the cables up and out

of the way will result in less exposure to

dirt and traffic.

C A U T I O N

!

LEPS5001 Power Supply - Installation

9