Aerobell 168 - introduction, Hose specifications – Ransburg Aerobell 168 A12787 User Manual
Page 29

Aerobell 168 - Introduction
LN-9270-12.3
26
HOSE SPECIFICATIONS
Function
Hose Characteristics
Paint Supply @Valve Manifold
6mm I.D. x 8mm O.D. PFA (.236” I.D. x 5/16” O.D.)
Turbine Supply @ Applicator
6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)
Turbine Braking Air Supply @ Applicator
6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)
Bearing Air Supply @ Applicator
6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)
Bearing Air Return @ Applicator
2.7mm I.D. x .4mm O.D. Nylon (.107 “ I.D. x 5/32” O.D.)
Shaping Air 1 @ Applicator
6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)
Sharping Air 2 @ Applicator
6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)
Interior and Bell Cup Exterior Rinsing Air/
Solvent
1/16” I.D. x 3/32” O.D. PFA
Dump @ Valve Manifold
6mm I.D. x 8mm O.D. PFA (.236” I.D. x 5/16” O.D.)
Pilot for all Microvalves
2.7mm I.D. x .4mm I.D. Nylon (.107 “ I.D. x 5/32” O.D.)
Paint Supply @ Applicator
1/4” O.D. Tube Fitting
Interior and Bell Cup Exterior Rinsing Air/
Solvent Supply @ Valve Manifold
6mm I.D. x 8mm O.D. PFA (.236” I.D. x 5/16” O.D.)
!
W A R N I N G
♦
Arcing/fire hazard exist if ungrounded
metal connections (air or fluid) are used
in the spray area. Use plastic non-
conductive connections, or ensure met-
al connections are at ground potential.
PFA* hoses must never be replaced with
Nylon hoses. Only Polyamide Nylon hoses
can be used for air connections. Polyure-
thane hoses are prohibited.
* PFA = Ultra Pure Polytetrafluoroethylene