Ransburg, Introduction, Specifications – Ransburg MMA-303 Direct_Ind Test Stand User Manual

Page 8: General information, Electrical / physical, Test specification summary, N o t e, Mma-303 test station - introduction

background image

Air Requirements:

1” NPT(F) Inlet

3/4” ID Air Line to

Stand 100 psi (6.4

bar) min. 0.3 to 0.6

Micron

Filtration

Dimensions

Height:

67” (1702 cm)

Width:

30” (762 cm)

Length:

48” (1219 cm)

Fluids:

Use distilled or

deionized water only

for

testing

Maximum Fluid

Pressure:

80 psi (5.2 bar)

INTRODUCTION

SPECIFICATIONS

Electrical / Physical

GENERAL INFORMATION

The Ransburg

Applicator Performance Test

Stand was developed to assist in determining the

applicator’s level of performance in an off-line con-

dition. Ensuring the applicator functions properly

after any maintenance has been performed to it

off-line reduces the costs associated with verifying

performance during production. With line speeds

critical to the through-put of a facility, every uptime

minute counts to underwrite profitability. This

Test Stand device helps to ensure the applicator

performs correctly when it is put into service.

This Test Stand will verify performance of single

fluid applicators, bearing air, shaping air, brake air,

turbine drive air, and fiber optic functionality. As

well, it checks kV and µA electrical performance

of the applicator.

The Test Stand was developed with the user and

the safety of the user in mind. The user must

become familiar with the overall function and

operation of the unit.

Output Voltage:

Indirect - 70 kV max.

Direct - 90 kV max.

Fluid Leaks:

No pressure drop for

2

minutes

Bearing Air

Flow Rate:

1.7 to 2.8 SCFM

Turbine Air Flow

at 70K RPM:

17 SCFM max.

Outer Shaping

Air Flow:

3-5 SCFM @ 25 psig

7-10 SCFM @ 60 psig

Inner Shaping

Air Flow:

4-7 SCFM @ 25 psig

10-13 SCFM @ 60 psig

Fiber Optic

Voltage:

.68V @ 50K RPM min.

Test Specification Summary

Ransburg

N O T E

†

For all test station toggle switches, with

the switch lever in the “UP” position, the

valve it describes is “ON” or “actuated.”

MMA-303 Test Station - Introduction

5

LN-9255-06.2