4

MMA-303 Test Station - Safety

AREA

Tells where hazards

may occur.

HAZARD

Tells what the hazard is.

SAFEGUARDS

Tells how to avoid the hazard.

Improper operation or mainte-

nance may create a hazard.

Personnel must be properly

trained in the use of this equip-

ment.

Personnel must be given training in accordance

with the requirements of NFPA-33.

Instructions and safety precautions must be read

and understood prior to using this equipment.

Comply with appropriate local, state, and national

codes governing ventilation, fire protection, opera-

tion maintenance, and housekeeping. Reference

OSHA, NFPA-33, and your insurance company

requirements.

General Use and

Maintenance

Electrical

Equipment

High voltage equipment is uti-

lized. Arcing in areas of flam-

mable or combustible materi-

als may occur. Personnel are

exposed to high voltage during

operation and maintenance.

Protection against inadvertent

arcing that may cause a fire

or explosion is lost if safety

circuits are disabled during

operation.

Frequent power supply shut-

down indicates a problem in

the system which requires

correction.

An electrical arc can ignite

coating materials and cause

a fire or explosion.

The power supply, optional remote control cabinet,

and all other electrical equipment must be located

outside Class I or II, Division 1 and 2 hazardous

areas (refer to NFPA-33).

Turn the power supply OFF before working on

the equipment.

Test only in areas free of flammable or combustible

material.

Testing may require high voltage to be on, but

only as instructed.

Production should never be done with the safety

circuits disabled.

Before turning the high voltage on, make sure no

objects are within the sparking distance.

LN-9255-06.2