Ransburg Evolver SE Robotic Atomizer A12455-XXXXXXXX User Manual
Page 19

AA-09-01.1 : Evolver SE
Section 4: OPERATION
•
Operators must be fully trained in safe operation of electrostatic equipment. Operators must read all
instructions and safety precautions prior to using this equipment (see NFPA-33).
•
Electrical discharge of a high electrical capacitance fluid/paint system can cause fire or explosion with
some materials. If arcing occurs when a specific coating material is used, turn the system OFF and
verify that the fluid in non-flammable. In these conditions, the system is capable of releasing suffi-
cient electrical and thermal energy to cause ignition of specific hazardous materials in the air.
WARNING
As with any spray finishing system, operation of the Evolver SE involves properly setting the operating parame-
ters to obtain the best finish quality for the coating material being sprayed while maintaining correct operation
and reliability of the equipment used. Adjustments to operating parameters, which cover spraying, cleaning,
and ON/OFF control, include the following:
•
Coating Materials
•
Fluid Flow Rate Control
•
Fluid Valve / Trigger Control
•
Atomization Air (paint atomization control)
•
Fan Air (pattern control)
•
Electrostatic Voltage
•
Target Distance