q. If the beam will not balance using the balance ball :

Check that the poise is at "0" and the poise screw is snug.

Check that the platform is 'free' and 'floating'.

Check that the beam load rod is connected properly on

BOTH ends.

• Check that there is nothing under the platform inhibiting

the levers (floor debris).

• Check that the counterpoise hanger, without any weights,

is on the tip loop.

• Check that the beam is hanging from the middle loop.

• Check that the beam lock is 'open'

• Apply a slight pressure to the scale platform and see if

the beam tip rises.

• If "YES" continue on to balance, if "NO", recheck

mechanical assembly.

If the scale beam still does not balance perform the following:

• Use a screwdriver to 'center' the balance ball at the butt

end of the beam.

• If the beam is "UP", apply small amounts of weight (BBs)

to the top of the counterpoise.

• If the beam is "LOW", remove the counterpoise hanger,

loosen the hanger rod by turning and holding the bottom

nut, and remove a small amount of lead shot.

• Add or remove small amounts of weight until beam

balances.

• Secure the counterpoise hanger with "added" or

"removed" weight.