Airvantage troubleshooting continued, Warning – Blagdon Pump AVX75 Metallic User Manual
Page 12
![background image](/manuals/346939/12/background.png)
avx75mdl1sm_haz duty-rev0112
Model AVX75 Hazardous Duty Metallic Page 10
CAPSCREW, HEX SOC, M6 X 35mm
COVER
SEAL, O-RING
VALVE, SOLENOID
VALVE, POPPET
SEAL, O-RING
CONTROL MODULE
O-RING
CAP, SWITCH
POWER GENERATOR MODULE
CAPSCREW, HEX SOC, M6 X 25mm
SEAL, O-RING
CAPSCREW, HEX SOC, M6 X 25mm
SEAL, O-RING
COVER
CAPSCREW, HEX SOC, M6 X 35mm
O-RING
O-RING
REGULATOR
WASHER, FLAT, M6
WASHER, FLAT, M6
Page 28
ITEM NO.
PART NUMBER
DESCRIPTION
032.054.000
1
171.092.115
CAPSCREW, HEX SOC, M6 X 35mm
8
2
258.020.147
COVER, END, ATEX
1
3
720.071.360
SEAL, O-RING
4
4
765.004.000
VALVE, SOLENOID
1
5
893.104.000
VALVE, POPPET
1
6
171.091.115
CAPSCREW, HEX SOC, M6 X 25mm
8
7
031.202.000
POWER GENERATION MODULE, ATEX
1
8
258.022.147
COVER, END, ATEX
1
9
020.069.000
REGULATOR
1
10
560.200.360
O-RING
2
11
249.019.000
CONTROL MODULE, RS20 HAZ. DUTY
1
12
560.104.360
O-RING
1
13
165.135.330
CAP, SWITCH
1
14
B27.7M - 3BM1-25
RING, RETAINER
1
15
430.050.147
HOUSING, MUFFLER
1
16
720.073.365
SEAL, DUST VALVE
1
17
HX-SHCS 0.125-40x0.188x0.188-N
CAPSCREW, HEX SOC HD, 5-40 X .25
1
18
BSI 4518 0221-16
O-RING
1
19
530.045.115
MUFFLER, SPARK ARRESTOR
1
20
165.137.115
PLATE, PERFORATED
1
21
535.096.000
TAG, WARNING
1
22
710.010.115
SCREW, SELF TAPPING, 4-24 X .25 LG
6
23
901.051.115
WASHER, FLAT, M6
8
24
535.094.000
TAG, NAME
1
AirVantage Troubleshooting Continued
AirVantage RESETS AND ENTERS LEARN MODE TOO FREqUENTLY
What to Check:
• Check for excessive varying environmental pumping conditions
(changing head or suction)
• Check ice buildup in exhaust area
• Inspect sleeve and spool set for damage
• Make sure patch cable plug is connected and locked
Corrective Action:
• Consult Factory After Sales Support Team
PUMP STALLS, RESETS, LEARNS, SEEKS AND REPEATS
What to Check:
• Make sure patch cable plug is connected and locked
• Check ice buildup in exhaust area
Corrective Action:
• Consult Factory After Sales Support Team
PUMP MOVES OUT OF STEADY STATE AND NEVER
ATTEMPTS TO RELEARN (LED ON)
What to Check:
• Make sure patch cable plug is connected and locked
• Cycle the power off/on to the control module
Corrective Action:
• Consult Factory After Sales Support Team
• Cycle the power switch on the control module off/on
WHAT TO DO IN THE EVENT OF A DIAPHRAGM FAILURE
If a diaphragm failure has been detected in pumps fitted with AirVantage,
see page 5 for shut-down procedure.
What to Check:
• Has product migrated to the sensor?
Corrective Action:
• If the sensor has been submerged in product, the sensor will need to be
replaced. Consult the AirVantage servicing section of the manual for detailed instructions.
What to Check:
• Has product contaminated the poppet valve?
Correct Action:
• If a significant amount of product has made it into the poppet valve, then the unit will
need to be disassembled for inspection. Consult the AirVantage servicing section (p.23).
Do not open when an
explosive atmosphere
may be present.
WARNING