Emtech Electronics BLU-CIF User Manual
Blu- cif interface board, Important
BLU- CIF Interface Board
BLU-CIF Cat5e Wiring Instructions
IMPORTANT:
IF you are using CAT5e wiring termination with the
BLU-CIF, then the RJ-45 connectors need to be crimped to TIA/EIA 568B
Standards (see below) on both ends of the cable. You must crimp and test
the wiring with an approved CAT5 568A/B tester before connecting any
cable between the BLU Products and the BLU-CIF Interface Board.
Failure to crimp wiring to the correct standard could possibly lead to
component damage.
EIA/TIA568B
1.
White-Orange
2.
Orange
3. White-Green
4.
Blue
5. White-Blue
6. Green
7. White-Brown
8.
Brown
The BLU-CIF Interface Board
simplifies the wiring of all of
the BLU products to the BSS
Audio London Series Digital
Signal Processors. It allows
for Cat5e wiring termination, as
well as, termination to 3.5mm
euro-style blocks. The BLU-
CIF accommodates connections
for the BLU-CC, BLU-CP,
BLU-CS, BLU-IR, BLU-SV,
BLU-SV8 or Emtech MSC-C
modules for combining audio in
overflow areas. It is designed
for mounting on the back door
of a 19” rack.