Appendices
A-1
Teledyne Analytical Instruments
Appendices
A.1
Specifications
Range:
0-100% oxygen
Accuracy:
+2% of full scale (at constant temperature)
Response Time:
90% in less than 8 seconds (typically 6-8 seconds at 25 °C)
Display:
Digital LCD with battery-life indication
Battery Life:
Approximately 1,000 hr. continuous use in a non-alarm
condition
System Power:
4 AA alkaline batteries.
Sensor Type:
Class T-7
System Enclosure:
7" W × 5" D × 2-1/2" H (178 mm × 127 mm × 63.5 mm)
Weight:
Less than 2 lb (Less than 1 kg)
Cable Length:
Retracted: 2 ft / Extended: 10 ft
Storage Temp.:
10-30 °C continuous, 0-50 intermittent °C
Operating Temp.:
0-40 °C
Stability: Less than 1% O
2
over an 8 hour period at constant pressure
and temperature
O
2
level alarm ranges:
Hi alarm: 18 to 100 Percent
Low alarm: 17 to 100 percent
O
2
level alarm accuracy:
Alarm thresholds digitally stored and alarm effectivity is
digitally compared against the value calculated by the
microprocessor. Hence, the accuracy of the alarms is the
same as the accuracy of the unit as specified above.
Warm up time:
Typically 20 minutes or less
A.2
Spare Parts List
QTY
PART NO.
DESCRIPTION
1
A51327
Micro-Fuel Cell T-7 with flow diverter P/N A50057
4
B99
“AA” size alkaline battery
- 1220 - Multipoint flammable gas and vapor detection system (50 pages)
- 212R - Thermal conductivity analyzer (28 pages)
- 235 - Thermal conductivity analyzer (38 pages)
- 275R - Portable turbine generator purge gas analyzer (21 pages)
- 2000A-EU - General purpose thermal conductivity analyzer (86 pages)
- 2000XTC - Thermal conductivity analyzer (40 pages)
- 2010A - Split architecture thermal conductivity analyzer (110 pages)
- 2010B - Split architecture thermal conductivity analyzer (98 pages)
- 2020 - Explosion proof thermal conductivity analyzer (80 pages)
- 2120 - Trace Nitrogen in Argon Analyzer (66 pages)
- 2120XL - Trace Nitrogen Analyzer (85 pages)
- 2230R - Process Hydrogen Analyzer (26 pages)
- 2240 – Portable Handheld Hydrogen Leak Detector, 3rd generation (updated 1/31/11) (30 pages)
- 2240 - Portable Handheld Hydrogen Leak Detector, 3rd generation (revision 2/29/08) (40 pages)
- 2240 – Portable Handheld Hydrogen Leak Detector, 2nd generation (13 pages)
- 2750 - Portable turbine generator gas analzyer (40 pages)
- 300P - Percent oxygen analyzer (24 pages)
- 306WA - Analog trace oxygen analyzer (46 pages)
- 311 - Portable trace oxygen analyzer (19 pages)
- 311D - Portable trace oxygen analyzer with digital meter (18 pages)
- 311XL - Portable trace oxygen analyzer (18 pages)
- 316RA / RB / RAD / RBD - Oxygen analyzers (24 pages)
- 319R - Oxygen analyzer (23 pages)
- 320 Series - Portable oxygen detectors (24 pages)
- 326, 327 and 328 - Oxygen analyzers (45 pages)
- 329R - Oxygen analyzer (22 pages)
- 335 - Analog control room monitor for personnel safety (24 pages)
- 356WA - Analog trace oxygen analyzer (42 pages)
- 3000MA - Paramagnetic oxygen analyzer (63 pages)
- 3000MA - Paramagnetic oxygen analyzer Addendum (2 pages)
- 3000MB - Paramagnetic oxygen analyzer (59 pages)
- 3000PA - General purpose percent oxygen analyzer (69 pages)
- 3000PAEU - General purpose percent oxygen analyzer (78 pages)
- 3000PB - Bulkhead mount percent oxygen analyzer (82 pages)
- 3000TA - General purpose trace oxygen analyzer (75 pages)
- 3000TA-EU - General purpose trace oxygen analyzer (89 pages)
- 3000TA-XLEU - Trace oxygen analyzer (108 pages)
- 3000TB - Bulkhead mount trace oxygen analyzer (78 pages)
- 3000TB-XL - Trace oxygen analyzer (78 pages)
- 3000ZA - Trace oxygen analyzer (81 pages)
- 3000ZA-3X - Trace oxygen analyzer (72 pages)
- 3000ZA2G - Zirconium oxide analyzer (72 pages)
- 3000 Ultra Trace - PPB oxygen analyzer (72 pages)
- 3010MA - Paramagnetic oxygen analyzer, includes 0-100% range (88 pages)
- 3010MA – Paramagnetic oxygen analyzer, no 0-100% range – (superceded) (88 pages)