8. Pump Details

8.1

Pump Dimensions

For installation dimensions and pump weights, please refer to a Pump General Arrangement drawing
or to pump information from the SPP RAPID electronic catalogue.

8.2

Eurostream Pump Connections



Suction & Delivery Flanges:


Auxiliary Connections:

Suction and Delivery

Flanges are drilled to

BS4504 PN16

with Raised Face

I


Pressure Gauge


Rp

¼


Except for sizes 100/26, 125/26, 80/32,
100/32, 125/32, 150/32, 100/40, 125/40, &

150/40 which are

Rp½


II


Suction Gauge


Rp

¼


III

Vent / Seal Flush


Rp

¼

All Sizes


VII


Casing Drain


Rp

3/4


Except sizes 32/13, 40/13, 50/13, 65/13,
32/16, 40/16, 50/16, 32/20, 40/20 &

50/20 which are

Rp¼