ADIC Scalar Series User Manual
Page 68

58
Diagnostics Menu
rr
=
Row number (01 - 2)
dd
=
Drive number (01 - 04)
This function is usually used for diagnostics only by a trained technician.
Place In Slot
The Place In Slot function will cause the Media Picker to place the cartridge into a storage slot.
p Use LEFT or RIGHT to select the desired field. Select the row and slot using UP or DOWN. Press ENTER
to activate.
rr
=
Row number (01 - 04)
ss
=
Slot number (01 - 12)
This function is usually used for diagnostics only by a trained technician.
Place In Mailbox (when Mailbox equipped)
The Place In Mailbox function will cause the Media Picker to place the cartridge into a Mailbox slot.
p Use LEFT or RIGHT to select the desired field. Select the MB row and slot using UP or DOWN. Press
ENTER to activate.
rr
=
Row number (01 - 2)
ss
=
Slot number (01 - 05)
This function is usually used for diagnostics only by a trained technician.
Place In Drive
The Place In Drive function will cause the drive door to open and the Media Picker to place the cartridge into the
drive.