Ontents, Rror, Messages – Avery ALS 256 User Manual
Page 56

52
C
ONTENTS
6.1 E
RROR
MESSAGES
ALS
20x
256
GB
5147
Tandemsynch. Init
This message can only appear
during tandem operation.
– Communication between the master
and slave machines is not function-
ing.
£
Check tandem interface cable.
– Is it a) in place and b) correctly con-
nected?
£
Check the settings on both ma-
chines.
– Siehe “Setting up tandem operation”
auf Seite 112.
5200
Home position
This message may appear when
operating the applicator. The ap-
plicator did not reach its home
position (upper end position)
within the intended time-frame.
– The applicator is stuck
– Compressed air applicator: Com-
pressed air supply interrupted or
switched off
– Cable not correctly connected.
£
Remove any obstructions
£
Check compressed air connection
and reconnect correctly if necessary
£
Check cable and connect correctly if
necessary.
5201
Touch Down
The applicator lower end position
(Touch Down) was not reached in time.
6002
New prog. vers.
New firmware has been loaded. This is a
message from the labeller that new
firmware is available.
£
Press the Online button to confirm.
– All parameters are reset to their fac-
tory settings.
6031
New Parameters
New firmware was loaded with the result
that new functions have been added to
the menu.
£
No action necessary. The message
is for information only.
6207
No file card
No compact flash card was found.
£
Check whether a compact flash card
is connected. If the compact flash
card was not connected until after the
machine was switched on: Switch the
machine off and back on again.
9022
No network link
This status message can only appear
when Ethernet address assignment is
set to DHCP (
INTERFACE PARA >
NETWORK PARAM.> IP Addressassign
). The
cause is almost invariably an incorrectly
plugged-in network connector.
£
Check whether the network connec-
tor is plugged in correctly, correct if
necessary.
Status
Status text
Cause
Action to take
[53]
List of error messages