beautypg.com

Alto-Shaam 500-E User Manual

Page 6

background image

1.

An identification tag is permanently mounted

on the cabinet.

2.

Plug the unit into a properly grounded

receptacle ONLY. Arcing will occur when

connecting or disconnecting the unit unless

all controls are in the “OFF” position.

3.

Position the unit so the cord is easily accessible

in case of any emergencies. If necessary, a

proper receptacle or outlet configuration, as

required for the unit, must be installed by a

licensed electrician in accordance with

applicable, local electrical codes.

230V:

To prevent an electrical shock hazard between the

appliance and other appliances or metal parts in

close vicinity, an equalization-bonding stud is

provided. An equalization bonding lead must be

connected to this stud and the other appliances /

metal parts to provide sufficient protection

against potential difference. The terminal is

marked with the following symbol.

NOTE:

The appliance must be connected to an

electrical circuit that is protected by an

external GFCI outlet.

Op e ra tio n a n d C a re Ma n u a l • 5.

I N S TA L L AT I O N

Electrical Installation

ELECTRICAL

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

kW

125

1

50/60

4.0

.50

208-240

1

50/60

4.4

1.10

230

1

50/60

4.3

1.0

230

1

50/60

3.3

.75

NEMA

6-15

P

, 15A-250

V PLUG

NEMA

5-15

P

, 15A-125

V PLUG

CEE 7/7, 220-230

V PLUG

500-E