10.9.

ACCUMULATED TOTAL

The scale can be set to accumulate when a weight is added to the scale

automatically or manually by pressing [Print]. See Section 13.2.

NOTE:

1.

The accumulation function is available only during weighing. It is disabled
during parts counting or percent weighing.

2.

The accumulated weights will be stored in either kg or lb, depending upon
the weighing unit in use.

3.

If at any time the weighing units are changed, the accumulated data will be
lost.

10.9.1

MANUAL ACCUMULATION

When the scale is set to manual accumulation, the weight displayed will be stored in

the memory when the [Print] key is pressed and the weight is stable.

Remove the weight and press [Print] when the scale is at zero. The
display will show "ACC 1" and then the weight in memory for 2 seconds
before returning to normal. The weight can be output to a printer or PC
using the RS-232 interface.