2 setting the backlight, 3 enabling the weighing units, Auto power off – Nova-Tech CQT Series User Manual
Page 12: Setting the backlight, Enabling the weighing units

5.2
SETTING
THE
BACKLIGHT
The backlight may be enabled or disabled by the user. If the backlight is disabled,
the battery life will be greater.
The following settings are available:
1 BL
Sets the backlight to operate automatically when a weight is
placed on the balance or a key is pressed.
2 BL
Sets the backlight to be on all the time.
OFF BL
Sets the backlight to be off.
1) To set this parameter turn the power off press and hold the [Tare] key then
press the [on/off] key once, then release the [Tare] key.
2) The display will show the first function PWR
3) Press the [Unit] key until the display shows XX BL where XX is the last setting
4) Press [Tare] key to select the settings as follows 1 BL ‐ 2 BL – OFF BL
5) Press the [Unit] key to confirm the setting
6) To exit turn the balance off and back on again
5.3
ENABLING
THE
WEIGHING
UNITS
You can enable and disable the weighing units available to the user when they press
the [Unit] key as described in section 4.4 Weighing Units.
1) To set this parameter turn the power off press and hold the [Tare] key then
press the [on/off] key once, then release the [Tare] key.
2) The display will show the first function PWR
3) Press the [Unit] key until the display shows you XX g where XX is the last
setting on or off.
4) Press the [Tare] key to select on or oFF.
5) Press the [Unit] key to move to the next weighing unit.
6) Repeat steps 5 and 6 until you have set all of the weighing units.
12 |
P a g e
© Adam Equipment Company 2008