beautypg.com

Multichannel Systems MEA1060-Inv Manual User Manual

Page 29

background image

Appendix

29

acquisition and filter
amplifier

System

amplification. 4 additional analog and 1 digital I/O port.
Complete with data acquisition computer, software package
and accessories. USB 2.0 High Speed data transfer with a
sampling rate of up to 40 kHz per channel.

USB-MEA256-System
with integrated data
acquisition and filter
amplifier, and
advanced perfusion

USB-
MEA256-
System-E

256-channel recording system with integrated data
acquisition from 256MEAs.252 recording channels,
4 additional analog and 1 digital I/O port. Complete with
data acquisition computer, software package and
accessories. USB 2.0 High Speed data transfer with a
sampling rate of up to 40 kHz per channel, temperature
controller and perfusion cannula.

USB-MEA32-System
with integrated data
acquisition, filter
amplifier, and
stimulus generator

USB-
MEA32-
STIM4-
System

32-channel recording system with integrated data acquisition
from perforated MEA-32S12-Lx. 32 recording channels,
12 stimulation channels, filter amplification and 4-channel
current stimulus generator STG, perfusion cannula PH01 and
suction port for low pressure. Complete with data acquisition
computer, software package and accessories. USB 2.0 High
Speed data transfer with a sampling rate of up to 50 kHz per
channel.

Accessories

Product

Product
Number

Description

Adapter for MEAs with
8 special electrodes for
stimulation

MEA-STIM-
Adapter

For use with MEAs 200/30-Ti-stim or 200/30-ITO-stim,
and MEA1060-Inv amplifier.

Holder with M3 threads

MPM3

For fixing tools with M3 threads next to the MEA.

1-Channel temperature
controller

TC01

2-Channel temperature
controller

TC02

PID based technology, set-point temperature reached
fast within 30 s to 5 minutes, control temperature
range from ambient temperature
to +50 °C.

Perfusion cannula with
programmable fluid
temperature

PH01

Temperature can be programmed with the
temperature controller TC01 or TC02.

Signal divider for MEA-
Systems

SD-MEA

Placed between a MEA1060 amplifier and MC_Card,
permits to select any channel, does not interfere with
the data acquisition, for example, for connecting an
oscilloscope or other devices to single channels.

Test Model Probe for
MEA1060 amplifiers

Test-MEA

Test model probe with CB-GND cable (for ground
connection). For all MEA1060 amplifiers.

Signal Generator for
MEA1060 amplifiers

MEA-SG

Signal generator for MEA-Systems: Can be placed in
MEA1060 amplifier. Simulates 12 different types of
sine curves and biological signals.

Signal Generator for
USB-MEA256-System

256MEA-SG

Signal generator for USB-MEA256-Systems: Can be
placed in USB-MEA256 amplifier. Simulates 12
different types of sine curves and biological signals.