beautypg.com

Hrc fuse recommended – Mody Pumps MS 252 User Manual

Page 5

background image


HRC FUSE RECOMMENDED

MAINS VOLTAGE AT SITE

MS 252

220 VOLTS, 3 PHASE 25

AMPS

380 VOLTS, 3 PHASE

15 AMPS

415 VOLTS, 3 PHASE

15 AMPS

460 VOLTS, 3 PHASE 15

AMPS




TROUBLE GUIDE CAUSE REMEDY

1.FUSES BLOWN. 1.REPLACE FUSES
2.CABLE DAMAGED 2.SHORTEN/REPLACE CABLE

PUMP DOES NOT START

3.NO POWER. 3.CHECK POWER SUPPLY

4.BLOCKED IMPELLER. 4.CLEAN BOTTOM PARTS.
5.STATOR WINDING BURNT. 5.REPLACE STATOR.

1.BLOCKED IMPELLER. 1.CLEAN BOTTOM PARTS.
2.IMPELLER ROT.WRONG 2.SHIFT TWO PHASE CONN.

PUMP STARTS BUT STOPS

. 3.CONNECTED FOR WRONG 3.CHECK & RECONNECT.

VOLTAGE.
4.VOLTAGE TOO LOW/HIGH. 4.APPROACH POWER CO.
5.LIQUID DENSITY HIGH 5.HIGHER HP REQUIRED.
6.BI-METAL TRIPS. 6.CHECK CURRENT.

1.IMPELLER ROT.BACKWARD. 1.SHIFT TWO PHASE CONN.
2.PUMP WORN DOWN. 2.REPLACE IMPELLER.

PUMP GIVES TOO LITTLE

3.LONG HOSE AND DIAMETER 3.CHECK PRESSURE LOSSES

WATER.

TOO SMALL.

4.PRESSURE HEAD TOO HIGH 4.INSTALL BIGGER PUMP.
5.WEARING RING WORN OUT. 5.REPLACE WEAR RING.