Mody Pumps M 100 T_316SS SERIES User Manual
Page 6

OVERLOAD PROTECTION
.
IT IS ESSENTIAL THAT A STARTER BE USED WHEN OPERATING THE PUMP. CHOOSE THE
CORRECT RATING OF STARTER AS PER THE NAME PLATE OF THE PUMP. THE OVERLOAD
SETTING ON THE STARTER RELAY SHOULD BE SET TO THE FULL LOAD CURRENT OF THE PUMP
AS INDICATED ON THE NAME PLATE. FOR SINGLE PHASE PUMPS A PANEL BOARD IS
NECESSARY.
SPECIAL CONTROL BOXES SUITABLE FOR THE PUMP ARE AVAILABLE WITH US INCORPORATING
ALL PROTECTIONS NECESSARY.
LUBRICATION
.
NO ROUTINE MAINTENANCE OR LUBRICATION IS NECESSARY. THE BEARINGS ARE GREASE
LUBRICATED AND SEALED FOR LIFE. THE MECHANICAL SEAL AND OIL SEAL RUN IN AN OIL
BATH. NO TOPPING UP IS NECESSARY BUT THE CONDITION OF THE OIL SHOULD BE CHECKED
ONCE IN SIX MONTHS. THIS IS BY FAR THE EASIEST WAY TO ASCERTAIN THE INTEGRITY
OF THE SEAL FACES. (REFER OVERHAUL INSTRUCTIONS)
TROUBLE SHOOTING
.
PROBLEM PROBABLE CAUSE REMEDY
1.FUSES BLOWN REPLACE FUSES
2.CABLE DAMAGED REPLACE CABLE
3.NO POWER CHECK POWER SUPPLY
PUMP DOESN'T START 4.BLOCKED IMPELLER CLEAN IMPELLER
5.WINDING BURNT REPLACE STATOR/REWIND
1.BLOCKED IMPELLER CLEAN IMPELLER
PUMP STARTS & STOPS
2.IMPELLER ROT.BACKWARDS REVERSE ROTATION
3.CONN.FOR WRONG VOLTAGE CHECK AND RECONNECT
1.IMPELLER ROT.BACKWARDS REVERSE ROTATION
2.PUMP WORN DOWN REPLACE WEAR PARTS
DISCHARGE TOO LOW 3.LONG HOSE & SMALL DIAM. USE LARGER DIAM.HOSE
4.DISCHARGE HEAD TOO HIGH USE LARGER PUMP
GENERAL OVERHAUL(REFER DRG. DW/041/00-SHEET 1&2
)
THE PUMP SHOULD BE OVERHAULED EVERY ONE YEAR (APPROX. 2500 WORKING HOURS)
UNDER NORMAL WORKING CONDITIONS. IF THE WATER BEING PUMPED CONTAINS A HIGH
PERCENTAGE OF SLUDGE AND ABRASIVES IT IS ADVISABLE TO DO THE OVERHAUL EVERY
SIX/EIGHT MONTHS (APROX. 2000 HRS). THE OVERHAUL INCLUDES REPLACEMENT OF SHAFT
SEAL, OIL SEAL, ETC., CHECKING THE ELECTRICAL SYSTEM, AND GENERAL INSPECTION OF
WEAR AND OTHER PARTS.