Health physics division, Dosidef_access module for restricted access to the, Dosixom fi les data transfer to the server – Mirion Technologies DOSIDEF User Manual
Page 2: Local data enrichment (mission defi nition), Local and utc time management for synchronizing, Readers local back-up, Populate reader with pre-allocation lists, Evaluation of the daily dose exposure and duration, Raw and net doses calculation, Background compensation capability

Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
BP 1
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technolgies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
Health Physics
Division
Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.
DOSIDEF
Active Dosimetry - Software
www.mirion.com
144643EN-B
SYSTEM ARCHITECTURE
DOSIDEF_ACQUISITION module for data collection
●
DOSIDEF_ACCESS module for restricted access to the
●
central database
DOSIDEF_CALC module for the dose calculation and
●
the database management
The 3 modules can be operated separately or on the
●
same PC
DOSIDEF_ACQUISITION MODULE
Data collection from deployed XOM readers or
●
DOSIXOM fi les
Data transfer to the server
●
Local data enrichment (mission defi nition)
●
Local and UTC time management for synchronizing
●
readers
Local back-up
●
Populate reader with pre-allocation lists
●
DOSIDEF_CALCULATION MODULE
Collected data analyzed prior to integration in the data-
●
base
Rebuilds chronology, detects and solves any problem
●
due to missing data or erroneous sequence of events
Residual, gamma fl ash and neutron fl ash doses management
●
Evaluation of the daily dose exposure and duration
●
Raw and net doses calculation
●
Background compensation capability
●
Dose compared with the preset limit thresholds
●
DOSIDEF_ACCESS MODULE
Administrative data management and display of the
●
dosimetry for individuals, cells, units or missions
Display all events occured on the fi led (readings)
●
Alarms and exceeded limits sorting
●
Data enrichment capability
●
XOM pre-allocation lists managment
●
Access to the dosimeter database for maintenance
●
purposes
Large choice of built-in reports
●
SYSTEM CONFIGURATION
PC-based confi guration for clients
●
Server size depends on population
●
Operates with Windows 98, 2000, XP
●
Compatible with ORACLE® and SQL_server® data
●
bases (not included)