Health physics division, Predefi ned assignment or allocation to any user, Preloaded alarm setpoints – Mirion Technologies DOSIFAST User Manual
Page 2: Preset for fast entry mode, Instantaneous dosimeter activation, Turn dosimeter on via a single button press), Post-use dosimeter reading and switching off, Sorting by alarm or pre-alarm events, User listing, sorted by issued dosimeters, Dose management options
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
BP 1
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technolgies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
Health Physics
Division
Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.
DOSIFAST
Active Dosimetry - Software
FUNCTIONAL CHARACTERISTICS
Preset dosimeter options:
●
predefi ned assignment or allocation to any user
○
preloaded alarm setpoints
○
preset for fast entry mode
○
Instantaneous dosimeter activation:
●
(turn dosimeter ON via a single button press)
○
Post-use dosimeter reading and switching off:
●
automated data acquisition when passing by a reader
○
(i.e. no user activity required)
optional pre-allocation to a specifi c user when the dosi-
○
meter is returned after use
Data Management options:
●
sorting by alarm or pre-alarm events
○
user listing, sorted by issued dosimeters
○
Dose Management options:
●
selectable accumulation period of one month, three
○
months, one year (calendar), 365 days (rolling), or fi ve
years
provides historical dose records
○
Reports options:
●
individuals or groups over selected periods
○
creates dose report forms for regulatory compliance
○
Manages software access levels (operator, supervisor,
●
administrator)
SYSTEM CONFIGURATION
Operating system: Windows 2000, XP or Vista
●
Integrated database (Microsoft ACCESS)
●
RS-232 / 485 or USB reader interface
●
Basic confi guration includes one PC and one reader
●
Additional readers can be added via local network
●
Remote workstations can be connected via local network
●
www.mirion.com
144626EN-B
Worker information
Select the allocated worker during preparation
Preparation
Thresholds
allocation or anonymous
Deactivation
Post use dose allocation
re-preparation or put in PAUSE
Activation
after pressing push button
Dosimeter inactive (not yet assigned)
Dosimeter waiting for activation
Dosimeter in operating mode