Parts and Instruction Manual -

Mirage 27” Propane Burnisher

Page 12


Based on the CO production rates shown above the TWA would be exceeded in a 100 x 500 x 10 foot
(empty) space after 6 hours with 2 air changes per hour. (Assumes no additional CO exposure during any 8 hour
time period),

The Graph above depicts the relationships of air exchange to time and CO ppm with cubic feet area and percent
CO emissions remaining constant.

Based on the CO production rates shown above the TWA would not be exceeded in a 100 x 750 x 10 foot (empty)
space after 8 hours with 2 air changes per hour. (Assumes no additional CO exposure during 8 hour time period)

The Graph above depicts the relationships of air exchange to time and CO ppm with cubic feet area and percent
CO emissions remaining constant.




1.5% CO 500,000cf

Hours of Operation

1

2

3

4

5

6

7

8

TWA (OSHA Method)

0 Change/hr

17

51

103

171

257

380

479

616

1/2 Change/hr

14

35

62

92

123

156

189

223

1 Change/hr

11

26

42

59

76

93

110

127

2 change/hr

7

16

24

33

42

50

59

67

8 Hour Time Weighted Average (OSHA Method)

1.5% CO 750,000cf

Hours of Operation

1

2

3

4

5

6

7

8

TWA (OSHA Method)

0 Change/hr

5

14

27

46

69

96

128

154

1/2 Change/hr

4

9

16

24

33

42

50

59

1 Change/hr

3

7

11

16

20

25

29

34

2 change/hr

2

4

7

9

11

13

16

18

8 Hour Time Weighted Average (OSHA Method)