Transmitter specifications – Max Machinery 290 Series Analog (295, 296 and G Series Transmitters) User Manual
Page 4

4
IH 295-200-350 • rev. 6/2011 • ©2010-11 Max Machinery, Inc.
an ISO 9001:2008 certified company
Transmitter Specifications
Supply Voltage
12 Vdc (Models 294-XXX-100 and G Series ending in B1 or D1)
24 Vdc (Models 294-XXX-000 and G Series ending in A1 or C1)
Supply Current Output
90 mA max@ 12 Vdc, 45 mA max@ 24 Vdc
Short Circuit Current
(1)
21 mA
Output Update rate
(2)
1 ms
Resolution
Adjustable without recalibration to any range of
± 10 Vdc
(Model 29X-3XX-XXX or
± 20 mA Model 29X-2XX-XXX)
Ambient Temperature Range
Transmitter (Storage)–40ºC to 85ºC (–40ºF to 185ºF)
Transmitter (Operation)
(3)
–40ºC to 80ºC (–40ºF to 175ºF)
Maximum Temperature, Process Fluid
(20ºC Ambient, 5V supply)
29X-X0X-XXX (Standard Model) 90ºC (195°F)
29X-X5X-XXX (High Temp Model) 155ºC (311°F)
Anti-dither Range
50% of a meter revolution - unidirectional - 2% bidirectional.
(software selectable from 1-100% of 1 revolution)
Signal Filtering
Software selectable from 1 ms to 250 ms time constant
( 1) Continuous Short Circuit is not recommended. The output current should not exceed 10 mA
(2) Events are seen as output transitions 1 ms after they occur
(3) Temperature of metered fluid will affect transmitter temperature, see graph