Disassembly, Initial disassembly – Magnum Venus Plastech Gel Coat Gun EMG-1500 User Manual
Page 14
EMG-1000 & EMG-1500 Gel Coat Gun
Disassembly
WARNING: Always remove fluid pressures before working on the unit.
WARNING: Be careful not to bend the catalyst and resin needles.
Initial Disassembly . . .
1.
Remove Catalyst, Resin and Air pressure from system before disassembly.
2.
Remove Catalyst, Resin and Air lines from the Gun Block Assembly.
3.
Remove Screw (00145) from Trigger Stud (54630-1).
4.
Remove Trigger Stud (54630-1) from Gun Handle and Trigger (MAX-2040).
5.
Remove Trigger (MAX-2040) from gun assembly.
6.
To remove the Gun Block Assembly (EMG-1001-01) from Gun Handle remove
Cap Screw (F-CS-04C-12) located at the back center, just above the Gun Block
Assembly.
You now have two components, the Gun Block Assembly and Gun Handle Assembly.
CHAPTER
1