Tools required, Release system pressure – Magnum Venus Plastech Auto Pro Gun CPC_CPG_CPT_PRTM-DG User Manual
Page 17

Automatic Pro Gun Manual
Rev. 06/2012
Page | 17
Tools required
You will need the following tools:
• Rubber mallet
• Thread Sealant
• Adjustable wrench
• Needle-nose pliers
• Flat-end screwdriver
• Lubriplate™ lubricant (08465)
• Scribe set (08126)
• Pro Gun ™ oil (04394)
• Turbulent Mixer Puller (6705-2-1)
• Seal Installation tool (58661-1)
• Alignment tool for resin seals (58663-1)
• Alignment tool for catalyst seals (58662-1)
• Pro Gun ™ screwdriver (9301-3-2) and packing bit (6705-1-1)
You should also have appropriate cleaning materials such as solvent, clean shop towels
or rags, a small brush, and empty containers into which you will flush the gun.
Also, you will need new o-rings and seals to replace the current ones in the Pro Gun™.
Please refer to the parts drawings to obtain proper parts numbers for the o-rings and
seals to be replaced.
Note: If you are using o-ring part number 01128 in the gun block, you do not need
to replace the o-ring unless it is showing obvious signs of wear. This o-ring is
specially designed to handle most solvents
Release System Pressure
1.
Turn off air supply to pumping system.
2.
Release fluid pressure from lines by holding the gun over an appropriate empty
container and pulling the trigger.
3.
Flush gun into appropriate container
4.
Turn off air supply to the solvent tank.
5.
Release any pressure in the flush tank by gently pulling upwards on the ring
attached to the pressure relief valve.
6.
Disconnect air line from rear of gun handle.