Magnum Venus Plastech GMX-2000 GRANIT COAT GUN User Manual
Page 14

14
Flush Valve Disassembly (5104-01-01)
1. Remove and discard the Flush Valve Split Seal (5104-21-1) from the Flush Valve
Body (5104-24-1)
2. Remove the Flush Elbow Assembly (5104-02-01) from the Flush Valve Neck (5104-
22-1)
3. Remove the Flush Valve Neck (5104-22-1) and the Flush Valve Seal (5104-26-1)
from the Flush Valve Body (5104-24-1). Discard the Flush Valve Seal (5104-26-1)
4. Remove the Flush Seal Body (5104-23-1) from the Flush Valve Button (5104-25-1)
5. Remove the Compression Spring (9203-2-3) form the Flush Valve Body (5104-24-1)
6. Remove and discard the O-Ring (7301-3-007) from the Flush Seal Body (5104-23-1)
7.
Remove and discard O-Ring (7301-13-008) from the Flush Valve Button (5104-25-1)
Catalyst Injector Assembly (5104-03-01) Disassembly
See drawing Injector Assembly (5104-03-01) for reference
1. Remove Injector Seal (5104-13-1) from Injector Body (5104-15-1)
2. Unscrew Plunger Retainer (5104-14-1) from Injector Plunger (5104-16-1)
3.
Remove Compression Spring (9203-2-2) from Injector Plunger (5104-16-1)
4.
Remove Injector Plunger (5104-16-1) from Injector Body (5104-15-1)
Note:
Discard all parts to be replaced by the repair kit. All remaining parts should be
thoroughly cleaned, inspected for damage, and replaced if necessary.