beautypg.com

Magnum Venus Plastech RT-5000 RTM INJECTOR TRIGGER User Manual

Page 18

background image

RT-5000 Remote Trigger Manual


Rev. 12/2012

Page | 18

Gun Control:


12. Mark both ends of the poly tube appropriately and put one end through the inner

guard and slide the hose clamp onto the tube and then attach it to the #5 barb
fitting (Gun “ON” signal). (see diagram above)


13. Attach the other end into the fitting located at the front of the Pro Gun. (see

drawing below)

14. Mark both ends of the poly tube appropriately and put one end through the inner

guard and slide the hose clamp onto the tube and then attach it to the #6 barb
fitting (Gun “OFF” signal). (see diagram above)

15. Attach the other end to the fitting located at the back of the Pro Gun. (see

drawing below)


Air Purge:

16. Mark both ends of the poly tube appropriately and put one end through the inner

guard and slide the hose clamp onto the tube and then attach it to the #7 barb
fitting (Air Purge). (see diagram above)


17. Push the other end into the push fitting located at the top of air purge portion of

the RTM Flush Valve mounted on the gun. (see drawing below)

Solvent Purge:

18. Mark both ends of the poly tube appropriately and put one end through the inner

guard and slide the hose clamp onto the tube and then attach it to the #8 barb
fitting (Solvent Purge). (see diagram above)


19. Push the other end into the push fitting located at the top of solvent purge portion

of the RTM Flush Valve mounted on the gun. (see drawing below)

Plug Assembly:

20. Install the inner guard into the two haves of the plug shell.

21. Install the four screws holding the outer shell of the plug together.