Magnum Venus Plastech RT-5000 RTM INJECTOR TRIGGER User Manual
Page 17

RT-5000 Remote Trigger Manual
Rev. 12/2012
Page | 17
Plug Disassembly:
1.
Remove the four screws holding the outer shell of the plug together.
2.
Remove the inner guard from the plug shell. Remember to put the tubing
through the inner guard before connecting it to the barb fitting.
Air Supply In:
3.
Locate or create an air supply from the air manifold.
4.
Mark both ends of the poly tube appropriately and put one end through the inner
guard and slide the hose clamp onto the tube and then attach it to the #1 barb
fitting. (see diagram above)
5.
Connect the other end of the poly tube to the air supply fitting located on the air
manifold.
Valve:
6.
Mark both ends of the poly tube appropriately and put one end through the inner
guard and slide the hose clamp onto the tube and then attach it to the #3 barb
fitting (Valve “OFF” signal). (see diagram above)
7.
Push the other end into the push fitting located at the top of the Valve. (see
drawing below)
8.
Mark both ends of the poly tube appropriately and put one end through the inner
guard and slide the hose clamp onto the tube and then attach it to the #2 barb
fitting (Valve “OPEN” signal). (see diagram above)
9.
Push the other end into the push fitting located on the bottom of the air cylinder
of the Valve, just below the “OFF” signal. (see drawing below)
Reset Button:
10. Mark both ends of the poly tube appropriately and put one end through the inner
guard and slide the hose clamp onto the tube and then attach it to the #4 barb
fitting (Reset signal). (see diagram above)
11. Locate the reset port on the Resin Meter, push the other end of the poly tube
through the inner guard of the Resin Meter plug and slide the hose clamp onto
the tube and then attach it to the barb fitting (Reset signal on the Resin Meter).
(see diagram above)