PROBLEMS
POSSIBLE CAUSE

REMEDIES


CANNOT ENTER INTO

1. Front panel disabled.

1. Check "Front Panel Accessible Functions With Program

PROGRAMMING Disable" section of the manual.

PROCESS, BATCH, OR

1. User input not properly programmed.

1. Verify programming of User Input parameters

TOTAL VALUES WILL NOT 2. User input Snk/Sre jumper configured improperly. 2. Configure Snk/Src jumper.
RESET WHEN A MANUAL
RESET IS PERFORMED

PRESCALER, PRESETS, OR 1. Front panel disabled.

1. Verify programming of Access parameters.

OUTPUT TIME VALUES CAN 2. Check "Front Panel Accessible Functions With Program
BE VIEWED BUT NOT Disable" section of manual.
CHANGED

UNIT COUNTS WHILE 1. User input reset mode set for momentary reset. 1. Program User input to a maintained reset.
RESET IS ACTIVATED

OUTPUT WILL NOT RESET

1. User input not properly programmed. 1. Verify programming of the user input parameters


OUTPUTS NOT WORKING 1. Output board not installed.

1. Install output board.

2. Improperly wired.

2. Check wiring.

3. Incorrect output board.

3. Check output board.

4. Defective output board.

4. Check or replace output board.