MicroPro Operations Manual

Rev. 09/2012

Page | 17

Air Manifold Controls:

Familiarize yourself with the Air Manifold controls, which consist of the following
regulators and gauges:

MAIN AIR INLET VALVE – this is where the air supply to the unit is connected.
The valve turns On / Off the air supply to the unit.

PUMP PRESSURE GAUGE & REGULATOR – this is the regulator used to
control the air pressure for the Powerhead.

AIR PURGE GAUGE & REGUALTOR – this gauge & regulator are used to set the
pressure used to air purge the gun, mix chamber and mixer.

SOLVENT TANK GAUGE & REGULATOR – this gauge & regulator are used to
set the solvent flush pressure.

PRIMING BUTTON – the priming button is used to operate the pump without the
gun being open. The priming button sends an air signal to the safety over ride
valve to operate the air motor and pump while the gun remains closed.